Wfr136106 - 2Amp/250V 3Ag Slow Blow Fuse - Adc American Dryer Corp

Brand: ADC Laundry Parts
Part #: Wfr136106
$2.83

List Price: $4.35
🏭 Ships Directly from Manufacturer This item ships straight from our trusted supplier — saving you time and keeping things moving fast.
* Unsure about this part? Submit a " Part Number Research " request for assistance.
Brand New Part
Eligible For Free Shipping! Cart Minimum $145
Manufacturer Warranty Included - More info
Return & Cancellation Policy - More info

Description / Wfr136106 - 2Amp/250V 3Ag Slow Blow Fuse - Adc American Dryer Corp

2Amp/250V 3Ag Slow Blow Fuse
ADC / American Dryer Corp • OEM Replacement Part • Commercial Dryers
Wfr136106OEM Genuine

ADC Wfr136106 replacement part, American Dryer Corp Wfr136106, ADC commercial dryer 2amp/250v 3ag slow blow fuse, Wfr136106 OEM part

OEM replacement fuse, fuse holder, or fuse block for ADC American Dryer Corp commercial dryers. Protects circuits from overcurrent replace after a confirmed fault event and always after diagnosing and correcting the root cause.

⚠ Installation Note

Never install a higher-rated fuse than specified. The fuse rating must match the circuit design an oversized fuse will not protect the circuit and can cause fires or component damage.


🔍 What This Part Fixes

✖ Problem Symptoms

  • Circuit protected by fuse completely dead no power to controlled component
  • Fuse visibly blown or reads open on continuity test
  • Fuse blowing repeatedly after replacement

✓ What This Part Restores

  • Restores circuit protection and function
  • OEM-spec current and voltage rating for the protected circuit

🔧 Installation Overview

  1. Disconnect power before accessing fuse
  2. Test fuse with multimeter open on continuity test confirms failure
  3. Diagnose and correct the root cause before replacing a fuse that blows repeatedly indicates an active fault
  4. Replace with identical rating (amp and voltage) never install a higher-rated fuse
  5. Restore power and verify protected circuit operates correctly

📋 Part Details

DetailSpecification
Part NumberWfr136106
OEM BrandADC / American Dryer Corp
Part TypeFuse
ApplicationADC Commercial Dryers

❓ Common Questions

Q: A fuse keeps blowing what is the root cause?

A: A repeatedly blowing fuse indicates an active short circuit or overload condition in the protected circuit. Disconnecting loads one by one will help isolate the fault. Replacing the fuse without finding and correcting the fault will result in repeated failures and may cause damage.


Not sure this is the right part for your machine?

Our parts team can verify fitment by model number before you order.

Contact Us Form