Description / Wj20X25912 - Capacitor - Ge Haier Hotpoint

Capacitor
GE / Haier • Genuine OEM Parts
Wj20X25912GE / HaierAir Conditioner / Heat PumpAc Capacitor

GE Wj20X25912 capacitor replacement part air conditioner / heat pump

Genuine GE / Haier replacement run capacitor or start capacitor for GE and Haier room air conditioners and mini-splits. Run capacitors maintain motor running efficiency; start capacitors provide starting torque. Capacitor failure is the most common AC service repair.

⚠ Important Note

DANGER: Discharge capacitor before handling capacitors retain lethal voltage after power off. Never discharge through a screwdriver use a resistor.


🔍 What This Part Fixes

✖ Symptoms

  • AC fan or compressor not starting capacitor failed
  • AC motor running slow or humming run capacitor failed
  • Capacitor visually bulged or leaking replace immediately

✓ What This Restores

  • Correct motor starting torque and running efficiency
  • Correct capacitance (MFD) and voltage rating for motor

🔧 Installation Overview

  1. Disconnect power and discharge capacitor before service capacitors retain dangerous charge
  2. Discharge capacitor through a resistor (not a screwdriver) before handling
  3. Match capacitance (MFD) and voltage rating exactly never substitute a lower rating
  4. Replace dual-run capacitors as a complete unit never replace one section only

📋 Specifications

SpecificationValue
Part NumberWj20X25912
BrandGE / Haier
ApplianceAir Conditioner / Heat Pump
Part TypeAc Capacitor

❓ Common Questions

Q: How do I test an AC capacitor?

A: With power OFF and capacitor discharged: use a multimeter with capacitance setting. Test both MFD ratings on dual-run capacitors (e.g., 35+5 MFD). A reading within 10% of rated value is acceptable. A reading significantly below rated value, infinity (open circuit), or zero (short circuit) means the capacitor is failed and needs replacement.